Seismic Structural Mechanics: CEBC Chapter A3 & FEMA P-1100
Residential structures built prior to the 1980s in high-seismic zones (such as the Pacific Rim and Wasatch Fault regions) possess two critical structural vulnerabilities: unbolted mudsills and unbraced cripple walls. During ground acceleration, horizontal ground shear forces easily slide an unbolted house off its concrete foundation.
Where cripple walls exist (wood studs elevating the first floor above the concrete stem wall), the lack of shear panel stiffness creates a classic "soft-story" mechanism. Under lateral seismic load, the studs rack like a collapsing parallelogram, plunging the home into the crawl space, severing natural gas lines, and igniting post-earthquake conflagrations.
Anchor bolts must be minimum 1/2-inch diameter (5/8-inch in high seismic zones) embedded at least 7 inches into concrete, spaced no more than 6 feet on center for one-story and 4 feet on center for two-story homes. Every mudsill piece must have at least two bolts, with one located between 4 and 12 inches from each end of the timber. Square 3" x 3" x 1/4" steel plate washers are mandatory under IRC Section R403.1.6 to prevent bolt pull-through.